MAINTENANCE
HPR400XD Manual Gas Instruction Manual 5-57
Torch lead test
1. Turn OFF all power to the system.
2. Locate the start-circuit assembly.
H8
WORK
H9
NOZZLE
H8
WORK
H9
NOZZLE
+–
D1
D2
DANGER
SHOCK HAZARD: Always use caution when servicing a power supply when plugged in and the covers
are removed. Dangerous voltages exist within the power supply which could cause injury or death.
3. Install a temporary jumper wire
between H8 (work) and H9
(nozzle) on the start circuit
PCB1.
4. Locate the pilot arc relay (CR1) and remove the dust cover. Have a second person close the contact.
5. Measure the ohm value between the nozzle and the plate. The reading should be less than 3 ohms. A measurement
of greater than 3 ohms indicates a faulty connection between the torch and ignition console or between the ignition
console and the power supply.
6. Verify that the pilot arc wire on the torch lead is not damaged. If it is damaged replace the lead. If it is not damaged,
replace the torch head.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR400XD and is the answer not in the manual?

Hypertherm HyPerformance HPR400XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR400XD
CategoryCutter
LanguageEnglish

Related product manuals