INSTALLATION
3-12 HPR400XD Manual Gas Instruction Manual
Lifting the power supply
A strap kit (228336) for lifting the HPR400 is available from Hypertherm. The strap kit should only be used to lift the
HPR400 as outlined herein. Before using the strap kit, the customer understands and assumes exclusive responsibility
for supplying personnel trained and qualified to operate forklifts, cranes, hoists and other lifting devices to lift or move
the power supply. All movement of the power supply must be done in compliance with applicable local laws and
regulations. All handling equipment must be evaluated for each application and inspected and tested before each use.
The power supply can be moved by forklift, but the forks must be long enough to extend the entire length of the base.
Take care when lifting so that the underside of the power supply is not damaged. The customer agrees to observe and
ensure compliance with the following:
The straps and other handling equipment must comply with applicable local standards, laws and regulations.
The rated capacity, design factor, and efficiency rating of the lifting system, including the straps sold by
Hypertherm, may be affected by wear, misuse, overloading, corrosion, deformation, intentional alteration, age,
and other use conditions. An inspection of the straps by qualified personnel should be conducted before each
use. Worn or damaged straps may not be used, nor may they be altered or modified in any way.
All 4 loops at the ends of the straps must be securely and properly attached to the lifting mechanism.
The power supply is a nonsymmetrical load; ensure that an analysis by a qualified person is performed properly
to balance the load to prevent tipping and overloading of any one strap.
All enclosure panels must be securely fastened before lifting the power supply.
The lifting mechanism must be rated for the appropriate weight and be suitable for the strap size.
Each strap should pass through all 4 holes in the base of the power supply and should not be twisted,
constricted, bunched or pinched.
Straps shall not be shortened or lengthened by knotting, twisting, choker hitching, or other means.
The power supply should be lifted slowly, not more than 203 mm (8 in.) above the floor, to insure that the weight
is evenly distributed.
The power supply should be moved slowly to prevent sudden acceleration and deceleration when moving.
Access to the area should be restricted when moving or lifting to prevent injury of personnel if the power supply
shifts or tips.
DANGER
The HPR400XD power supply weighs approximately 746 kg (1645 lbs). 1 or 2
person manual pushing or lifting could cause injury. Use appropriate lifting aids
and techniques when moving a power supply.
Correct path for lifting straps

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR400XD and is the answer not in the manual?

Hypertherm HyPerformance HPR400XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR400XD
CategoryCutter
LanguageEnglish

Related product manuals