HyPrecision Predictive waterjet pump Operator Manual 810120 155
7 – Troubleshooting
Troubleshooting
An error occurred during stage 4 of the start sequence.
Make sure that the cutting head is off.
Adjust the Pierce timer on the Start-procedure Timers screen. Refer to Operate the pump on page 60.
An error occurred during stage 5 of the start sequence.
Make sure that the cutting head is turned off.
Adjust the Cut timer on the Start-procedure Timers screen. Refer to Operate the pump on page 60.
Starting and stopping the motor rapidly can cause damage to the motor.
Wait longer between stopping and starting the motor.
The SMI senses that the high-pressure seal life remaining is between 8 hours and 50 hours.
Replace the seal. Refer to Water on page 166.
Warning: Start Procedure Ramp to Pierce Pressure
Warning: Start Procedure Ramp to Cut Pressure
Warning: Too Many Motor Starts in 15 Minutes
Warning: Left Dynamic Seal
Warning: Right Dynamic Seal
Warning: Left Static Seal
Warning: Right Static Seal