156 HyPrecision Predictive waterjet pump Operator Manual 810120
7 – Troubleshooting
Troubleshooting
Faults
The hydraulic fluid is too hot.
Refer to Temperature on page 162.
The intensifier is overstroking.
Refer to The intensifier overstrokes in 1 direction on page 158.
The supply pressure is lower than 2.8 bar (280 kPa / 40 psi).
Increase the supply pressure.
Pressure is lost because of a leak.
Identify the source of a leak and correct the problem.
The supply water is turned off.
Turn ON the supply water.
The hydraulic fluid is too hot.
Refer to Temperature on page 162.
The temperature sensor in the hydraulic fluid tank has failed.
Replace the sensor.
A hydraulic fitting or a hydraulic hose is leaking.
Fix the leak. Refer to Leaks on page 165.
Fault 1: Hydraulic Fluid >65C
Fault 1: Intensifier 1 Overstroke to Left
Fault 1: Intensifier 1 Overstroke to Right
Fault 1: Low Inlet Water Pressure
The water pressure at the manifold is lower than the minimum setting.
Fault 2: Hydraulic Fluid >65C for >3 Minutes
Fault 2: Hydraulic Fluid 45C Sensor
Fault 2: Hydraulic Fluid Level is Low
The float switch in the hydraulic fluid tank monitors the fluid level.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision Predictive P-50S and is the answer not in the manual?

Hypertherm HyPrecision Predictive P-50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision Predictive P-50S
CategoryWater Pump
LanguageEnglish

Related product manuals