EasyManuals Logo
Home>Hypertherm>Water Pump>HyPrecision Predictive P-50S

Hypertherm HyPrecision Predictive P-50S User Manual

Hypertherm HyPrecision Predictive P-50S
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
HyPrecision Predictive waterjet pump Operator Manual 810120 135
5 – Preventive maintenance
Preventive maintenance
Prepare for storage
1. Remove the water filters from the filter canisters. Refer to Replace the water filters on page 93.
2. Make sure that the filter canisters are empty.
3. Install the water filter canisters without the filters.
4. Disconnect the compressed air supply hose from the utility panel and connect it to the C
UTTING WATER IN
connection.
The C
UTTING WATER IN connection is 1/2-inch female. An adapter (not included) is necessary.
5. Disconnect the W
ASTE WATER OUT hose from the utility panel.
6. On the operator interface, touch the symbol on the Prepare for Storage screen.
Refer to Prepare for storage on page 129.
The cutting water and the cooling water supply valves open.
7. Turn
ON the compressed air supply for a minimum of 5 minutes to dry the system.
8. Turn
OFF the compressed air supply.
9. Disconnect the compressed air supply hose from the C
UTTING WATER IN connection.
10. Water can collect in the filter canisters when the system is cleared. Make sure that the filter canisters are
empty.
11 . Install the water filter canisters with the filters.
12. Drain hydraulic fluid from the hoses and the heat exchanger.
13. Do this procedure for a water-cooled system.
a. Connect the compressed air supply hose to the C
OOLING IN connection.
The C
OOLING IN connection is 1-inch NPT female. An adapter (not included) is necessary.
b. Disconnect the C
OOLING OUT hose from the utility panel.
c. On the operator interface, touch the symbol on the
Prepare for Storage screen.
The cutting water and the cooling water supply valves open.
d. Turn
ON the compressed air supply for at least 2 minutes to dry the system.
e. Disconnect the compressed air supply hose from the utility panel.
f. On the operator interface, touch the X symbol on the screen to close the water valves.
14. Install the fitting caps and the plugs on the utility panel.
Do not dry the cooling circuit of an air-cooled system.
High-pressure water can cause eye injuries. Wear approved eye protection when operating or
doing work near this equipment.
Do not stand over components such as tubes or valves while drying the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision Predictive P-50S and is the answer not in the manual?

Hypertherm HyPrecision Predictive P-50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision Predictive P-50S
CategoryWater Pump
LanguageEnglish

Related product manuals