172 HyPrecision Predictive waterjet pump Operator Manual 810120
7 – Troubleshooting
Troubleshooting
Operator interface
Operation screen
When the quantity of fluid leaking from the intensifier is less than a set threshold, the intensifier symbol on the
primary operation screen is in its usual state.
Alarms
The controller monitors the pump while it is operating. When the controller senses a problem that is likely to
cause damage to the equipment, the operator interface shows an Alarms screen and the beacon light flashes.s.
SMI-related alarms are described here. All other alarms are described starting on page 152.
Alarm screen on
the operator
interface
Beacon light Intensifier Primary motor Cause
Warning
Amber, flashing Enabled On
The SMI senses that
the seal life remaining is
between 8 hours and
50 hours.