222 HyPrecision Predictive waterjet pump Operator Manual 810120
9 – Installation
Installation
Pump Fault Behavior
Seal Maintenance Indicator
For information about faults and warnings, refer to
Troubleshooting section, which begins on page 149.
Empty Dirty Water
Reminder This turns the reminder feature on or off.
Reminder Time This timer determines how long the pump operates before the reminder is displayed.
The default is 200 hours.
Boost Fault
Monitor
The system can monitor an internal or external boost pump for fault conditions. This turns
monitoring on or off.
Fan Fault Monitor
The system can monitor an external heat exchanger for fault conditions. This turns monitoring
on or off.
Indicator On
This turns the Seal Maintenance Indicator (SMI) on or off.
Stop On Fault
This turns the Stop On Fault feature on or off.
When this feature is on, the pump operates for 30 minutes after a fault is sensed and then turns off.
Warning
The Seal Maintenance Indicator senses leaks from the intensifier. This value determines the number
of units that cause a warning.
The default is 5 units.
Fault
This value determines the number of units that cause the system to turn off.
The default is 20 units.
Sleep
If a fault occurs and the Stop On Fault feature is not on, this timer determines how long after a fault
is acknowledged that the system pauses before showing the
Alarms screen again.
The default is 2.0 hours.