64 HyPrecision Predictive waterjet pump Operator Manual 810120
4 – Operation
Operation
Stage 5: Increase the pressure to the cut pressure setpoint
1. The hydraulic pressure increases.
2. The Cut timer starts.
The timer is set at 5 seconds by default.
3. The intensifier strokes to increase water pressure in the system.
4. The timer expires.
If the time between intensifier strokes is longer than the Intensifier timer setpoint, pressure in the system is
sufficient..
The start sequence is complete
The pump is at operating pressure and is ready to use.
The beacon light is steady green.
The primary motor is on.
The hydraulic pump is on.
The intensifier is on.
The output water pressure shows on the screen.
If the time between intensifier strokes is shorter than the intensifier timer, pressure in the system is too low.
A Start Warning: Ramp to Pierce Pressure alarm shows on the screen. The beacon light flashes amber.