88 HyPrecision Predictive waterjet pump Operator Manual 810120
5 – Preventive maintenance
Preventive maintenance
4. Use the grease gun to put the specified quantity of grease in the motor.
5. Let the motor operate with the grease outlets open for 20 to 30 minutes.
6. Clean grease from the outside of the grease outlet and replace the relief plug.
7. Do this procedure again on the other end of the motor.
The grease gun should deliver approximately 1.25 grams of grease for each pump or 5 grams
for every 4 pumps. The manufacturer can give you the pump volume.
HyPrecision P-15
HyPrecision P-30
HyPrecision P-50
HyPrecision P-50S
HyPrecision P-60S
HyPrecision P-75S
20 grams 30 grams 40 grams
It is possible that used grease does not come out of the grease outlet when the new grease
is pumped in. Use only the recommended volume.