EasyManuals Logo
Home>Hypertherm>Welding System>MAX200

Hypertherm MAX200 User Manual

Hypertherm MAX200
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
MAX200 Instruction Manual 4-35
9-99
OPERATION
PAC200T/PAC200E Hand Torch
Aluminum
200 amps
N
2
Plasma / Air Shield
This gas combination is used when cut edge quality is less important. Electrode life is extended when this
combination is used.
Piercing above 7/8 inch (22 mm) not recommended.
* If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
Plasma
Gas
Type
Plasma Gas
Pressure
TEST/RUN
Shield
Gas
Type
Shield
Gas
Pressure
Arc
Current
Setting
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Plasma
Gas Inlet
Pressure
Shield
Gas Inlet
Pressure
(Inches) (mm) (psi) (psi) (Inches) (mm) (amps) (volts) (ipm) (mm/min) (sec) (psi) (psi)
3/16 5
N
2
34-38* / 54-54 Air 70 1/8 3 200 130 180 4570 0.5 120 90
1/4 6 1/8 3 135 160 4060 1.0
3/8 10 1/8 3 135 120 3050 1.5
1/2 12 1/8 3 140 80 2030 2.0
5/8 15 .157 4 140 70 1780 2.0
3/4 20 3/16 5 150 50 1270 2.5
7/8 22 1/4 6 160 35 890 2.5
1 25 1/4 6 165 25 635
1-1/4 32 1/4 6 175 20 510
1-1/2 38 1/4 6 185 10 250
Material
Thickness
Torch-to-work
Distance
Travel Speed
(60 SCFH) (280 SCFH)
020918
Shield
020608
Nozzle
020915
Retaining cap
020415
Electrode
020607
Swirl ring

Table of Contents

Other manuals for Hypertherm MAX200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MAX200 and is the answer not in the manual?

Hypertherm MAX200 Specifications

General IconGeneral
BrandHypertherm
ModelMAX200
CategoryWelding System
LanguageEnglish

Related product manuals