Three-phase power cord and plug installation
The Powermax1650 power supplies are shipped with a 6 AWG 4-wire UL/CSA power cord on
CSA units. A 10 mm2, 4-wire HAR power cord is provided on CE units. To operate the
Powermax1650, use a plug that meets national or local electrical codes. The plug must be
connected to the power cord by a licensed electrician.
L1
#10
Ground (PE)
L2
6” (152 mm)
9.5” (241 mm)
Route power cord
through strain
relief and tighten.
Power switch
Ground (PE)
L1
L3
Strain relief
Strain relief
inserts (2)
1. Strip and prepare the power cord wires as shown below:
Power cord installation
2. Connect the power cord to the power switch.
Note: On CE power supplies, L1, L2, and L3 are threaded through 2 ferrites before being
attached ot the switch.
L3L2
CSA CE
L1 Black Black (U)
L2 White Blue (V)
L3 Red Brown (W)
Ground
(PE)
Green Green/Yellow