Code Function Result Text message Action
015 USB interface Aborted Can NOT test USB interface while it is in use.
Note: If you have a USB keyboard or mouse
attached, you cannot run the diagnostic program
for the USB interface.
1. Turn off the
computer.
2. Replace the USB
keyboard and
mouse with a
standard keyboard
and mouse.
3. Turn on the
computer.
4. Run the diagnostic
test again.
Failed System board Call for service.
020 PCI interface Failed System board Call for service.
030 SCSI interface Failed SCSI adapter in slot n failed register/counter/
power test
(where n is the slot number of the failing adapter)
Refer to the information
provided with the
adapter for instructions.
If the problem persists,
call for service.
SCSI controller on system board failed
register/counter/power test
Call for service.
175 System thermal Failed Fan # n
(where n is the number of the failing fan)
Replace the indicated
fan.
Temperature sensed on processor board is out of
range
Call for service.
180 Status display Failed Any failure message Call for service.
201 System memory Failed RIMM is in location RIMM n
(where n is the number of the socket that contains
the failing RIMM)
1. Reseat the failing
RIMM.
2. If the problem
remains, replace the
RIMM.
If the problem
persists, call for
service.
Test setup error: Corrupt BIOS in ROM If your computer does
not have the latest level
BIOS installed, update
the BIOS to the latest
level.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS, information
in BIOS is not as expected
206 Diskette drive Failed Internal diskette drive bay Call for service.
215 CD-ROM Failed On system board. Call for service.
Aborted The CD-ROM drive is not present. Verify that the cables
are properly connected
to the CD-ROM drive.
If the problem persists,
call for service.
217 Hard disk drive Failed BIOS drive # n (where n is the drive bay number) Call for service.
56 IntelliStation M Pro: User Guide