3. Is the reference code occurring on a Model 270, 800, 810, 820, or 825 system unit, or an FC 5074,
FC 5075, FC 5078, FC 0578, FC 5079, FC 5088, FC 0588, FC 5094, FC 5095, FC 9074, FC 9079, or
FC 9094 I/O Expansion?
v Yes: Continue with the next step.
v No: See symbolic FRU ACMODUL in the Migrated Expansion Tower Problem Analysis, Repair and
Parts manual on the V5R1 Supplemental Manuals web site
. for FRU isolation instructions.
4.
Find the model and or feature code in the table below, then go to the Locations table for the model
you are working on to find the part number and remove and replace procedure information. Note that
on some models and feature codes, “Power PIP11” on page 175 must be performed before replacing
parts.
Table 1. Part replacement for unit reference code for Models 270, 800, 810, 820, 825, 870/890 (FC
9094)
Model
Unit reference
code Failing item
Model 270 00AC P01, P02
Models 800, 810 00AC P01, P02
Model 820
(“Power PIP11” on page 175 must be performed before replacing parts)
00AC P01, P02, P03
Model 825 00AC P01, P02
Models 870/890, FC 9094
BPC-A/B P00 and M41 VPD to CB1 (FC 9094), VSCOMM cable
00AC Cable: PWR23 (See
the Power and
signal cables page,
and follow the
Models 870 and 890
processor towers
link.)
FC 5075 00AC P01, P02
FC 5078, FC 0578, FC 5088, and FC 0588
(“Power PIP11” on page 175 must be performed before replacing parts)
00AC P01, P02
FC 5074, FC 5079, FC 9074, and FC 9079 (single line cord) 00AC P01, P02, P03
FC 5074, FC 5079, FC 9074, and FC 9079 (dual line cord)
(“Power PIP11” on page 175 must be performed before replacing parts)
00AC
1. P01, P02
2. A01, A02
FC 5094 and FC 9094 (dual line cord)
(“Power PIP11” on page 175 must be performed before replacing parts)
00AC
1. P00, P01, P02,
P03
2. A01, A02
FC 5095 00AC P01, P02
5. For Models 870/890 with reference code 00AC, if the problem still prevails, perform “MAPPWR-3: An
open room EPO switch has been detected from one side” on page 368.
This
ends the procedure.
ACMODUL instructions for Models 830, 840, SB2, and SB3
Note: The C in the SRC (1xxC xxxx) indicates the problem is on the processor tower side of the Model
840 system type.
1. Is SRC 1xxx 00AC displayed?
v Yes: On the system unit, the 00AC reference code can be caused by an SPCN frame-to-frame
cable problem. This usually occurs between the Model 840/SB3 processor tower and the FC 9079
Analyze hardware problems 269

Table of Contents

Other manuals for IBM iSeries 820

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 820 and is the answer not in the manual?

IBM iSeries 820 Specifications

General IconGeneral
BrandIBM
ModeliSeries 820
CategoryServer
LanguageEnglish

Related product manuals