This ends the procedure.
12.
Is the SRC 1xxx 2330 or 2331?
v No: Continue with the next step.
v Yes: The failing item is power supply 1 on a base expansion unit:
– FC 5033 - part 21H9364
– FC 5034 (as installed) - part 21H9364 or 44H7779
– FC 5035 - part 44H7779
Note: FC 5035 may contain up to 4 power supplies. The reference code that sent you here refers
to the power supply on the base expansion unit. See the Locations and Addresses section in
Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1 Supplemental
Manuals web site
.
This
ends the procedure.
13. Is the SRC 1xxx 2213?
v No: Continue with the next step.
v Yes: See the next failing item.
This ends the procedure.
14. Is the SRC 1xxx 2210?
v No: Go to “Starting point for all problems” on page 2.
This ends the procedure.
v Yes: The failing item is power supply 1 on the base expansion unit, or power supply 2 on the
internal expansion unit of an FC 5035 expansion:
– FC 5033 - part 21H9364
– FC 5034 (as installed) - part 21H9364 or 44H7779
– FC 5035 (power supply 2) - part 44H7779
Note: See the Locations and Addresses section in the Migrated Expansion Tower Problem
Analysis, Repair and Parts manual on the V5R1 Supplemental Manuals web site
.
This
ends the procedure.
QSYSOPR
For use by authorized service providers.
For more information, look in the System Operator message queue for a message with the same date and
time. Perform any actions defined in the message.
REDH
For use by authorized service providers.
The processor has received a memory error, however, analysis has determined this is most likely due to a
previous processor error than a memory failure.
Perform the following:
1. Look in the Service Action Log for a processor error (B4xx) occurring prior to this B4xx xEBF error and
replace any FRUs associated with that error.
Analyze hardware problems 443