v FRU or sensor returned to “normal” operating range (for threshold sensors)
Removing and replacing covers on a 7063-CR1 system
Learn how to remove and replace the covers on an IBM 7063-CR1 Hardware Management Console
system so that you can access the hardware parts or service the system.
Removing the service access cover from a 7063-CR1 system
Learn how to remove the service access cover from an IBM 7063-CR1 Hardware Management Console
system.
About this task
Attention: For safety, airflow purposes and thermal performance, the service access cover must be
installed and fully seated before you power on the system.
Procedure
1. Ensure that you removed both power cords from the system. For instructions, see “Disconnecting the
power cords from a 7063-CR1 system” on page 80.
(L005)
CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when
shorted with metal, which might result in splattered metal, burns, or both. (L005)
2. Remove the two cover screws (1), from the rear of the cover.
3. Press both buttons on the top cover (2) to release the latches as shown in Figure 67 on page 76, and
push the cover back about 0.5 in (1 cm) until it stops. If the buttons do not easily press down,
partially remove the drives directly under the buttons.
Common procedures for servicing the 7063-CR1 75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power Systems 7063-CR1 and is the answer not in the manual?

IBM Power Systems 7063-CR1 Specifications

General IconGeneral
BrandIBM
ModelPower Systems 7063-CR1
CategoryServer
LanguageEnglish

Related product manuals