EasyManuals Logo
Home>IBM>Server>RS/6000 Enterprise Server M80

IBM RS/6000 Enterprise Server M80 Installation Guide

IBM RS/6000 Enterprise Server M80
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Step 3. Checking the Customer Environment
Check the customer environment as follows:
v Verify with your installation planning representative or the customer that any
station-protector boxes used are correctly installed according to the
Site and
Hardware Planning Information
manual.
v Make sure the customer is aware that the recommended temperature for this system
is 24° C (75° F) and the recommended relative humidity is 45%. The following are
the acceptable operating ranges:
Temperature: 10° C (50° F) to 38° C (100° F)
Humidity: 8% to 80%
v Make sure the customer is aware that the front and rear service clearances around
the CEC drawer and rack should be 36 inches (900 mm). The service clearances are
important for proper air circulation, weight distribution, and safety to both the service
representative and the customer.
Chapter 1. Setting Up the System 3

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals