To install the2x81.8-inch SSDs with26GBperformance optimized HBA
adapters option in the server, complete the following steps.
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 40.
2. Turn off the server and disconnect all power cords and external cables (see
“Turning off the server” on page 28).
3. Remove the server cover (see “Removing the cover” on page 54).
4. Remove the two 4-drive filler panels that are to the right of drive bay 8,
beneath the IDs8-15onthefront bezel.
4-drive
filler panel
5. To obtain more working room, remove fans 2 and 3 (see “Removing a
dual-motor hot-swap fan” on page 123).
6. Install the new backplane assemblies.
eXFlash 1.8-inch drive cage
and backplane assembly
7. Connect the following cables in the order listed:
v Configuration cable 1
v SAS signal cables 2
v Power cable 3
Chapter 2. Installing optional devices 85

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650 M4 Type 7915
CategoryServer
LanguageEnglish

Related product manuals