Removing the fan cage assembly
To remove the fan cage assembly, complete the following steps:
1. Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 33.
2. Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3. If the server is in a rack, slide the server out of the rack.
4. Remove the top cover (see “Removing the server top cover” on page 36).
5. Lift the fan cage assembly release latches and rotate the release latches up until
the assembly disengages from the chassis; then, lift the fan cage assembly out
of the server.
Release
latch
Release
latch
Fan cage
assembly
Slots
Slots
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 116.
40 System x3750 M4 Types 8722 and 8733: Installation and Service Guide