Removing the microprocessor air baffle
This information provides instructions for removing the microprocessor air baffle.
About this task
To remove the microprocessor air baffle, complete the following steps:
Procedure
1. Read the safety information and installation guidelines, see “Safety” on page vii
and “Installation guidelines” on page 35.
2. Turn off the server (see “Turning off the server” on page 22) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3. Remove the top cover (see “Removing the server top cover” on page 38).
4. Grasp the baffle by the grip points, lift it all the way up out of the slots, and
set the baffle aside.
Note: A microprocessor air baffle must be installed whenever the two DIMM
connectors closest to the microprocessor (on the left and the right) are empty.
For example, when DIMM connectors 6 and 7 on the system board are empty,
the microprocessor air baffle must be installed on microprocessor 1. This is
applicable for all microprocessors.
Microprocessor
air baffle
Attention: For proper cooling and airflow, replace the air baffle before you
turn on the server. Operating the server with the air baffle removed might
damage server components.
Results
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 129.
Chapter 2. Installing optional devices 41