23
REMOTE CONTROL
Remote control (CI-V) information
D Command formats
• DV Digital code squelch setting
Command: 1B 07
First digit: 0 ~ 9
Second digit: 0 ~ 9
1
XX
• DV MY call sign setting
Command: 1F 00
Set your own call sign and note of up to 12 characters�
See “Character’s code of the call sign�”
X X X X X X X X X X X X
9
1
8
∙∙∙∙∙∙∙∙
1 ~ 8: Your own call sign setting (8 characters)
9 ~ : Note setting (4 characters)
• DV TX call signs setting
(24 characters or 8 characters)
Command: 1F 01
Set “UR,” “R1,” and “R2” call signs of 8 characters
(fixed), or only the “UR” call sign�
See “Character’s code of the call sign�”
When setting “UR,” “R1,” and “R2” call signs
X X
∙∙∙∙∙∙∙∙
X X X X X X X X X X
∙∙∙∙∙∙∙∙
9
1
8
∙∙∙∙∙∙∙∙
X X X X
1
8
∙∙∙∙∙∙∙∙
1 ~ 8: UR (Destination) call sign setting
(8 characters)
9 ~ : R1 (Access/Area repeater) call sign setting
(8 characters)
~ : R2 (Link/Gateway repeater) call sign setting
(8 characters)
When setting only the “UR” call signs
1 ~ 8: UR (Destination) call sign setting
(8 characters)
Character’s code of the call sign
Character ASCII code
0 ~ 9 30 ~ 39
A ~ Z 41 ~ 5A
(Space) 20
/ 2F
• DV TX message setting
Command: 1F 02
Set the transmit message of up to 20 characters�
See “Codes for character entries�” (p� 19)
“FF” stops sending or reading messages�
• Repeater tone/tone squelch frequency settings
Command: 1B 00, 1B 01
100Hz digit: 0 ~ 2
10 Hz digit: 0
~ 9
1 Hz digit: 0
~ 9
0.1 Hz digit: 0
~ 9
Fixed digit: 0*
Fixed digit: 0*
1*
00 X X X
2 3
X
*Not necessary when setting a frequency.
• DTCS code and polarity setting
Command: 1B 02
0 (fixed)
First digit: 0 ~ 7
Second digit: 0 ~ 7
Third digit: 0 ~ 7
Receive polarity: 0=Normal
1=Reverse
Transmit polarity: 0=Normal
1=Reverse
1
XX 0 X X
2 3
X
• Data mode with lter width settings
Command: 1A 06
1
X X X X
2
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF*
01=Data mode ON
*
When 00 is set, also set 00 to 2.