Page #75 background imageLoading...
Page #75 background image
Boiler Information
Lockout History
a
b
c
d
e
f
b
b
b
b
a
b
c
d
e
f
b
b
b
b
a
b
c
d
e
f
b
b
a
b
c
d
e
f
b
b
a
b
c
d
e
f
b
b
b
b
a
b
c
d
e
f
b
b
b
b
Lockout History
1. Blower speed 5h ago
2. DHW Sensor Open 2h ago
3. Sensor Drift 25 h ago
4. No error 27 h ago
5. No error 27 h ago
6. No error 27 h ago
Lockout Details
Blower speed
Boiler Status --
Heating Call --
DHW Call --
Boiler Firing Rate 44%
Ionization current 44μA
Low Water
Water pressure has fallen below
7.2 psi. Increase pressure
to normal range.
If problem persists,
call for service
E37
63
CHAPTER 9
CHAPTER 9 - CTRLMAX OPERATION
Lockout History records the last eight lockouts. Six lines are dis-
played on the Lockout History screen at one time. Each line contains a
lockout description followed by how long ago the lockout occurred.
Touch the
or soft keys to scroll through the items then touch
to select and get more details through the Lockout Details screen.
The following information items are recorded at the time of a lockout:
Boiler Status
Heating Call
Domestic Call
Boiler Firing Rate
Flame Ionization Current
Boiler Setpoint
Boiler Supply Temperature
Boiler Return Temperature
Boiler Flue Temperature
Outdoor Temperature
System Temperature
9.14.2 Lockout Screen
If a problem occurs, the Lockout Screen replaces the
Home Screen. The backlight will remain on until the
lockout is reset.
Touching any arrow soft key will return to the Home
Screen so that additional troubleshooting can be per-
formed. See Sections 9.14.3 on page 64 and 9.14.4 on
page 65 for a list of lockouts and descriptions.
Select the Home Screen icon at the bottom of any
screen to return to the lockout screen.
Lockout reference code. Refer to Sections 9.14.3
on page 64 and 9.14.4 on page 65 for more
information.
Lockout text. The rst sentence describes the lockout,
the second sentence gives a possible cure, and the third
tells how to reset the lockout.
Lockout message.

Table of Contents

Other manuals for IDEAL EXALT COMBI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL EXALT COMBI and is the answer not in the manual?

IDEAL EXALT COMBI Specifications

General IconGeneral
BrandIDEAL
ModelEXALT COMBI
CategoryBoiler
LanguageEnglish

Related product manuals