Installation and Servicing
Section 2 - Installation
INSTALLATION
2.20 INSTALLER WIRING - CONTINUED
br
br
o
g/y
b
b
g/y
g
g
LN
E
LNE
CH
ON
R/S
ON
HW
ON
HW
OFF
C/S
ON
FUSED
SPUR
TIMER
CH ONLN
HW ON
HW
S PLAN
VALVE
CH
S PLAN
VALVE
R/S
o
BOILER
LN
MAINS IN
SL 1
EIN
OUT
HW OFF
C/S
Logic + System
2
S BOILER WITH S PLAN SYSTEM (without outside sensor)
2.21 REPLACING PRE-FITTED MAINS CABLE
Strain
Relief
If it is necessary to use an alternative mains cable to the one pre-tted
then use the following guide.
Replacement wiring should comply with notes and be carried out by a
qualied person.
1. Isolate the mains supply to the boiler.
2. Remove the front panel.
3. Swing the control box down into the service position, unclip and
swing back the installer wiring cover to latch into the retaining clips.
4. Unscrew the L N & connections & remove wires from connector.
5. Remove the mains cable by pulling back through the grommet .
6. Route the replacement through the grommet and re-t.
7. Close the installer wiring cover ensuring that it is located correctly
and that the cable is retained into the strain relief as shown.
6
8. Swing the control box back up into the operating position and re-t the front panel ensuring a good seal is made.
The earth connection should be longer than the current carrying connections. If the cord anchorage slips, the current carrying
wires become taut before the earth.
Refer to Section
2.19
Wiring External to the Boiler
The fuse rating should be 3A.
Wiring external to the boiler MUST be in accordance with the current
I.E.E. (BS.7671) Wiring Regulations and any local regulations.
Frost Protection
If parts of the pipework run outside the house or if the boiler will be
left o󰀨 for more than a day or so then a frost thermostat should be
wired into the system.
The frost thermostat should be sited in a cold place but where it can
sense heat from the system.
If the boiler is installed in a garage it may be necessary to t a pipe
thermostat, preferably on the return pipework.
EXAMPLE - Connection to Honeywell Evohome
(for additional information visit www.honeywelluk.com)
2.22 ELECTRICAL CONTROLS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC+ SYSTEM2 S30 and is the answer not in the manual?

IDEAL LOGIC+ SYSTEM2 S30 Specifications

General IconGeneral
BrandIDEAL
ModelLOGIC+ SYSTEM2 S30
CategoryBoiler
LanguageEnglish

Related product manuals