EasyManuals Logo
Home>Idex>Control Unit>HALE MIV 2.0

Idex HALE MIV 2.0 User Manual

Default Icon
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
17
ORIGINAL WIRING. WIRING DIAGRAMS ARE PROVIDED IN THE TROUBLESHOOTING
SECTION OF THIS MANUAL.
FOLLOW NFPA REQUIREMENTS FOR APPARATUS ELECTRICAL WIRING. USE MINIMUM
14 AWG, TYPE SXL OR GXL (SAE J1128) WIRE. THE WIRING SHALL BE PROTECTED
USING 289
O
F (143 C) MINIMUM FLAME RETARDANT, MOISTURE RESISTANT LOOM OR
BRAID.
Figure 7. MIV PANEL PLACARD MOUNTING DIMENSIONS
2.
Connect the wiring harness from the panel placard to the wiring harness from the gearbox
adapter. The Packard WeatherPack end connectors are keyed and will only assemble one
way.
3.
Connect +12 VDC power to the RED pigtail provided using 14 AWG type SXL or GXL (SAE
J1128) wire. Make sure the power supply is capable of providing 12 VDC power at 10
AMPS. Connect the end of the BLACK wire to a ground point on the chassis frame. Make
sure the wires are routed away from sources of heat and avoid sharp edges. Make sure all
wires are protected with loom and connections are sealed to protect them from the under-
truck environment.
4.
If required a handwheel extension is provided in the installation kit. The extension is made
to mount in one of two positions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Idex HALE MIV 2.0 and is the answer not in the manual?

Idex HALE MIV 2.0 Specifications

General IconGeneral
BrandIdex
ModelHALE MIV 2.0
CategoryControl Unit
LanguageEnglish