MD280/MD280N User Manual Parameter Description
189
Group C The Second Motor Parameter
Rated power
Factory default
value
Model dependent
FC-00
Setup range 0.2kW to 1000.0kW
Rated voltage
Factory default
value
Model dependent
FC-01
Setup range 0V to 480V
Rated current
Factory default
value
Model dependent
FC-02
Setup range 0.1A to 6553.5A
Rated
frequency
Factory default
value
Model dependent
FC-03
Setup range
0.00Hz to maximum frequency˄F0-04˅
No-load current
Factory default
value
Model dependent
FC-04
Setup range
0.1A to 6500.0A
Stator
resistance
Factory default
value
Model dependent
FC-05
Setup range 0.001ȍ to 65.535ȍ
The function code defines the parameter of the second motor,please refers to
F1-00 to F1-03ˈF1-15ˈF1-16 for details.
Caution˖
1ǃ The motor selection can be determined via DI
terminal function 32 and “stwiching of the first motor
and the second motor”
2ǃ V / F curve of No. 2 motor is linear by default.
Torque hoist
Factory default
value
1.0%
FC-06
Setup range
0.0%˄auto˅ to 30.0%
Please refer to the description of function code F1-05.
Slip compensation coefficient
Factory
default
value
0.0%
FC-07
Setup range 0.0% to 200.0%
Please refer to the description of function code F1-13.
FC-08
Oscillation
suppression gain
Factory default
value
Model dependent
efesotomasyon.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD280 Series and is the answer not in the manual?

Inovance MD280 Series Specifications

General IconGeneral
BrandInovance
ModelMD280 Series
CategoryInverter
LanguageEnglish

Related product manuals