Operation, Display and Application Examples
- 48 -
Key Name Function
Stop/Reset
Stop the AC drive when it is in the running state and perform the
reset operation when it is in the fault state. The functions of this
key are restricted in F7-02.
Multifunction
Perform function switchover (such as quick switchover of
command source or direction) according to the setting of F7-01.
Menu mode
selection
Perform switchover between menu modes according to the
setting of FP-03.
4.2 Viewing and Modifying Function Codes
The operation panel of the MD380 adopts three-level menu.
The three-level menu consists of function code group (Level I), function code (Level II), and
function code setting value (level III), as shown in the following gure.
Figure 4-2 Operation procedure on the operation panel
F0
F0-03
5
(Select the function
code group)
(Select the
function code)
(Set the value of
the function code)
Level-I menu
Level- II menu
Level- III menu
PRG
PRG
Not to save
the setting
ENTER
To save
the setting
ENTER
50.00
ENTER
Status parameter
PRG
F0
-
04
ENTER
PRG
Next function
code
(default display)
If there is a blinking digit , press
/ / to modify the digit .
You can return to Level II menu from Level III menu by pressing
or
.
• After you press
, the system saves the parameter setting first, and then goes
back to Level II menu and shifts to the next function code.
• After you press
, the system does not save the parameter setting, but directly
returns to Level II menu and remains at the current function code.
Here is an example of changing the value of F3-02 to 15.00 Hz.
Figure 4-3 Example of changing the parameter value
50.00 F0
F3 F3-00
ENTER
F3 F3-03
015.00 010.00
F3-02
010.00
ENTERPRG
PRG
PRG
ENTER