6.2 Proceed for Door operator commissioning:-
6.2.1 For Auto Door
NICE 1000 system is capable for double side door operator system (Front and Back Doors)
Door Open Limit and Door Close Limit switches feedbacks are mandatory for NICE 1000 system
function (to be connected to X14 and X18 Default input terminals for Front door)
Field Wiring Diagram suitable for NICE 900 Door Drive with NICE1000 Controller
If the third party door drive system is used, follow the door drive commissioning instruction and
commission the door drive along with NICE1000 input and output interconnections as shown in above
model wiring diagram
Follow the commissioning procedure provided by door operator system supplier
Once door operator function is completed successfully, Elevator is ready for Normal operation with
rated speed
L U
N V
E W
NICE900 +24VDC
Door Drive PG-A
PG-B
PG-Z
COM
COM TA1
DI1 TC1
DI2 F9-09=2 TB1
DI3 TA2
DI4 TC2
DI5 (F9-05=1) TB2
DI6 (F9-06=2) TA3
DI7 TC3
DI8 F9-11=1 TB3
+24VDC
X14(F5-14=22) Y6
Y7
Y8
Y9
YM1
X18(F5-18=24)
Power
Supply
Motor
MCTC-MCB