After completion of Door operator commissioning and NICE1000 shaft learning process, Lift is ready
for normal operation. Now the lift car will be located in top most floor terminal level and the
corresponding input terminal sequence will be seen in the NICE1000 Main Control Board LEDs as
shown in the below table
Functional Command Sequence at Main Control Board (MCB) on NICE unit
Door Close Command (Y7 relay gets ON)
Door Fully opened
Door In between
Door Fully Closed
Remark
DOL
DCL
X14ON
X18OFF
X14OFF
X18OFF
X14OFF
X18ON
Improper
Sequence can
lead to Err53
Car Door Safety
Landing Door Safety
X26OFF
X27OFF
X26OFF
X27OFF
X26ON
X27ON
Door Open Command (Y6 relay gets ON)
Feed Back Signal
Door Fully Closed
Door In between
Door Fully opened
Remark
DOL
DCL
X14OFF
X18ON
X14OFF
X18OFF
X14ON
X18OFF
Improper
Sequence can
lead to Err53
Car Door Safety
Landing Door Safety
X26ON
X27ON
X26OFF
X27OFF
X26OFF
X27OFF
Door Fully Closed
Door Fully Opened
Door in between