Intel® Server Board S1200BT TPS Appendix D: POST Code Errors
Revision 1.0
Intel order number G13326-003
135
POST Error Beep Codes
The following table lists POST error beep codes. Prior to system video initialization, the BIOS
uses these beep codes to inform users on error conditions. The beep code is followed by a
user-visible code on POST Progress LEDs.
Table 60. POST Error Beep Codes
Beeps
Error Message
POST Progress Code
Description
3
Memory error
Multiple
System halted because a fatal error related to the memory
was detected.
The following Beep Codes are from the BMC, and are controlled by the Firmware team. They are listed here for
convenience.
1-5-2-1
CPU socket
population error
N/A
CPU1 socket is empty.
1-5-2-4
MSID Mismatch
N/A
MSID mismatch occurs if a processor is installed into a
system board that has incompatible power capabilities.
1-5-4-2
Power fault
N/A
DC power unexpectedly lost (power good dropout) Power
unit sensors report power unit failure offset
1-5-4-4
Power control fault
N/A
Power good assertion timeout Power unit sensors report
soft power control failure offset

Table of Contents

Other manuals for Intel S1200BTLRM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200BTLRM and is the answer not in the manual?

Intel S1200BTLRM Specifications

General IconGeneral
BrandIntel
ModelS1200BTLRM
CategoryServer Board
LanguageEnglish

Related product manuals