Intel® Server Board S1200BT TPS BIOS User Interface
Revision 1.0
Intel order number G13326-003
► Real-time Temperature and Voltage Status
Figure 31. Hardware Monitor Screen, Auto Fan Control (S1200BTS)
► Real-time Temperature and Voltage Status
CPU Fan
Hysteresis
Default Fan PWM
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/100%]
System Fan
Hysteresis
Default Fan PWM
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/100%]
Auxiliary Fan 1
Hysteresis
Default Fan PWM
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/100%]
Auxiliary Fan 2
Hysteresis
Default Fan PWM
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/100%]
Figure 32. Hardware Monitor Screen, Manual Fan Control (S1200BTS)
6.5.2.17 Realtime Temperature and Voltage Status
The Realtime Temperature and Voltage Status screen allows the user to view displays of
current processor and system fan speeds, current system temperature, and the status of
various voltages which are monitored on the board.