Intel® Server Board S1200BT TPS Platform Management
Revision 1.0
Intel order number G13326-003
45
Alerts that signify fault conditions that should be recorded in the system SEL will be sent to the
Integrated BMC by the ME using the IPMI Platform Event Message command. The Integrated
BMC deposits such events into the SEL.
The external software must configure the Integrated
BMC‘s PEF and alerting features to then send that event out as an IPMI LAN alert, directed to
the software application over the LAN link.
Alerts that provide useful notification to the external software for NM management, but do not
represent significant fault conditions that need to be put into the SEL, will be sent to the
Integrated BMC using the IPMI Alert Immediate command. This requires that the external
software application provide the NM on the ME with the alert destination and alert string
information needed to properly form and send the alert.
The external software must first
properly configure the alert destination and string in the Integrated BMC LAN configuration
using standard IPMI commands, then provide the associated selectors to the Integrated BMC
using the ―Set Node Manager Alert Destination‖ OEM command.
4.4.3.2 BIOS-Integreated BMC-ME Communication
In this generation of platforms, the BIOS communicates directly with the ME via HECI.

Table of Contents

Other manuals for Intel S1200BTLRM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200BTLRM and is the answer not in the manual?

Intel S1200BTLRM Specifications

General IconGeneral
BrandIntel
ModelS1200BTLRM
CategoryServer Board
LanguageEnglish

Related product manuals