Output Commands
Copyright © Itech Electronic Co., Ltd. 31
Chapter7 Output Commands
OUTPut[:STATe] <bool>
This command sets the output state of the power supply.
Syntax
OUTPut[:STATe] <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
OUTP ON
Query syntax
OUTPut[:STATe]?
Returns
0|1
[OUTPut:]PROTection:CLEar
This command clears the protection status.
Syntax
[OUTPut:]PROTection:CLEar
Arguments
None
Example
PROT:CLE
Query syntax
None
Returns
None