Source Commands
Copyright © Itech Electronic Co., Ltd. 56
Syntax
[SOURce:]VOLTage:UNDer:PROTection:DELay <NRf+>
Arguments
<NRf+>
Default value
10.00S
Example
VOLT:UND:PROT:DEL 10.00
Query syntax
[SOURce:]VOLTage:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
This command enables or disables the under-voltage function.
Syntax
[SOURce:]VOLTage:UNDer:PROTection:STATe <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
VOLT:UND:PROT:STAT ON
Query syntax
[SOURce:]VOLTage:UNDer:PROTection:STATe?
Returns
0|1
[SOURce:]VOLTage:UNDer:PROTection:WARM
<NRf+>
This command sets the under-voltage warm-up time of the power supply.