Source Commands
Copyright © Itech Electronic Co., Ltd. 50
Default value
0.01S
Example
CURR:SLEW:POS 1.000
Query syntax
[SOURce:]CURRent:SLEW:POSitive? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command sets the voltage value of the power supply. The query form of
this command gets the set voltage value of the power supply.
Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MINimum
Example
VOLT 60.00
Query syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage[:LEVel]:LIMit[:HIGH] <NRf+>
This command sets voltage upper limit under CC priority mode.
Syntax
[SOURce:]VOLTage[:LEVel]:LIMit[:HIGH] <NRf+>
Arguments
<MINimum-MAXimum>|MINimum|MAXimum