Source Commands
Copyright © Itech Electronic Co., Ltd. 49
Default value
MAXimum
Example
CURR:SLEW 0.5,0.5
Query syntax
[SOURce:]CURRent:SLEW[:BOTH]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]CURRent:SLEW:NEGative <NRf+>
This command sets the current falling slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:NEGative <NRf+>
Arguments
NRf+
Default value
0.01S
Example
CURR:SLEW:NEG 1.000
Query syntax
[SOURce:]CURRent:SLEW:NEGative? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]CURRent:SLEW:POSitive <NRf+>
This command sets the current rising slew rate of the power supply.
Syntax
[SOURce:]CURRent:SLEW:POSitive <NRf+>
Arguments
NRf+