List Commands
Copyright © Itech Electronic Co., Ltd. 71
LIST:CURRent:LIMit[:POSitive] <NRf+>
This command sets the current positive limit of list program.
Syntax
LIST:CURRent:LIMit[:POSitive] <NRf+>
Arguments
<MINimum-MAXimum|MINimum|MAXimum>
Example
LIST:CURR:LIM 20
Query syntax
LIST:CURRent:LIMit[:POSitive]? [MINimum|MAXimum]
Returns
NR3
LIST:CURRent:LIMit:NEGative <NRf+>
This command sets the current negative limit of list program.
Syntax
LIST:CURRent:LIMit:NEGative <NRf+>
Arguments
<MINimum-MAXimum|MINimum|MAXimum>
Example
LIST:CURR:LIM:NEG 20
Query syntax
LIST:CURRent:LIMit:NEGative? [MINimum|MAXimum]
Returns
NR3
LIST:SAVE <NR1>
This command saves the present list program into the specified memory.
Syntax
LIST:SAVE <NR1>