Source Commands
Copyright © Itech Electronic Co., Ltd. 44
Query syntax
[SOURce:]CURRent [:LEVel]:LIMit:POSitive?
Returns
NR3
[SOURce:]CURRent[:LEVel]:LIMit:NEGative <NRf+>
This command sets negative current limit value of power supply.
Syntax
[SOURce:]CURRent [:LEVel]:LIMit:NEGative <NRf+>
Arguments
<MINimum-MAXimum>|MINimum|MAXimum
Default value
0.0
Example
CURR:LIM:NEG MAX
Query syntax
[SOURce:]CURRent [:LEVel]:LIMit:NEGative?
Returns
NR3
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]
<NRf+>
This command sets the output current value when the power supply receives a
trigger.
Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MIN
Example
CURR:TRIG 3.500