Multi-Machine Operation
Online: indicates the instrument is in the synchronized relationship. At this
time, the front panel [Link] key light is lit.
Offline: indicates the instrument is not in the synchronized relationship and
the front panel [Link] key light is off.
You can enter into the system menu to set the status(Online/Offline) of the
instrument, or you can short press (1 s or so) the front panel [Link] key to
switch the synchronization status of the instrument. Long pressing (about 3 s)
[Link] key can display the current synchronization status of the instrument. At
this time, pressing [Enter] key can enter into the synchronization menu setting
interface. You can set parameters such as synchronized mode or On/Off delay
time.
Take the synchronized relationship among single instrument and multiple
parallel groups for instance, the detailed connection method and procedures
are as follows.
1. Configure the channel number of each instrument. Please refer to 8.1 Multi-
Channel Function for detailed introduction.
2. Connect the instruments according to the above diagram.
a. Connect system bus interfaces.
Copyright © Itech Electronic Co., Ltd.