Technical Specification
Current Temperature
Coefficient
50ppm/℃
Regulation
Load
Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Line
Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Ripple
Ripple
Voltage ≤1200mVp-p
Current ≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
30ms
Rise time
Voltage(Full load)
60ms
Fall time
Voltage(No load)
30ms
Fall time
Voltage(Full load)
30ms
Transient
Response
Time
Voltage
≤2mS
Output Protection range
OCP -3.1A or 3.1A
OVP 610V
OPP -210W or 210W
External analog (optional)
Voltage programming
External 0V~10V is 0~600V
Voltage monitoring
External 0V~10V is 0~600V
Current programming
External -10V~10V is -3A~3A
Current monitoring
External -10V~10V is -3A~3A
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 1Aac (AC220V)
DC Offset
-0.1A~+0.1A
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Copyright © Itech Electronic Co., Ltd.
132

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3412 and is the answer not in the manual?

ITech IT-M3412 Specifications

General IconGeneral
BrandITech
ModelIT-M3412
CategoryPower Supply
LanguageEnglish

Related product manuals