Inspection and Installation
RS–232 Configuration
The user needs to configure the RS–232 interface parameters in the system
menu before using the remote control. The RS–232 interface parameters are as
follows.
Name Description
Baud rate Select the baud rate from the following options: 4800/9600/
19200/38400/57600/115200
Data Bit 8 (fixed)
parity bit None (fixed)
stop bit 1 (fixed)
The operation steps are as follows.
1. Press [Shift]+[P-Set](System) to enter into the system menu interface.
2. Use left and right keys or rotate the knob to select I/O Config and press
[Enter] key to confirm.
3. Use left and right keys or rotate the knob to select RS-232 and press [Enter]
key to confirm.
1RS232 = 9600_8_N_1
4. Rotate the knob to set the baud rate and press [Enter] to confirm.
5. Press [Esc] to exit.
RS-232 Troubleshooting
If you meet some problems when communicating with PC by RS-232 interface,
please check the following items:
PC and power supply must have the same baud rate.
Copyright © Itech Electronic Co., Ltd.
34

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3412 and is the answer not in the manual?

ITech IT-M3412 Specifications

General IconGeneral
BrandITech
ModelIT-M3412
CategoryPower Supply
LanguageEnglish

Related product manuals