Quick Reference
mode. If CC priority mode is selected,
the parameter setting of I-Fall Time will
be displayed here.
Output Res
Set the internal resistance of the power
supply. This parameter needs to be set
only when Mode is set to CV.
Sink Res
Set the CR function in sink mode. This
parameter needs to be set only when
Mode is selected as CC.
• OFF: Turn off the CR function.
• ON: Turn on the CR function and set
Sink Res. Setting range: 0~7500Ω.
Set Sink Res=0, which means to
turn off the CR function.
On Delay Set the delay time to turn on the output.
Off Delay Set the delay time to turn off the output.
Voltage Max
Set the upper limit of the voltage (de-
fault is the rated voltage of the instru-
ment). Once the voltage upper limit is
modified here, the parameters related
to the voltage setting will be limited by
the upper limit here.
The descriptions of configuration menu of the load are listed in the table below.
Config Configuration menu of the load
Mode
Set the operation mode
CC
Constant current operation mode
CV
Constant voltage operation mode
CW
Constant power operation mode
CR
Constant resistance operation mode
CVCC
CV+CC complex operation mode
CVCR
CV+CR complex operation mode
CCCR
CC+CR complex operation mode