Technical Specification
Parameter IT6018B-800-75
Setup stability-8h
(%of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Readback stability-
30min (%of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Readback stability-
8h (%of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Input impedance
quiescent current
<10mA at Vmax
Efficiency
~92%
Remote Sense
Compensation
Voltage
≤8V
Command Re-
sponse Time
2Ms
Storage
Temperature
-10℃~70℃
Protective Function
OVP, OCP, OPP, UVP, OTP, Vsense protect
Standard Interface
Standard: USB, CAN, LAN, VCP,
optional: GPIB, RS232
Isolation (input to
ground)
1500V
Working
Temperature
0~50℃
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
*1. The instrument needs to be customized under other AC input voltage
ranges. For models equipped with an emergency stop module (including AC
contactor), the AC input voltage range can only be: 342V~528V.
7.1.13 IT6018B-1500-40
Source Mode
Parameter IT6018B-1500-40
Rated value ( 0 ℃-50 ℃) Output Voltage
0~1500V
Copyright © Itech Electronic Co., Ltd.