Basic Operation
• Pin 8 controls the actual output voltage of the instrument from 0V to
500V.
• Pin 9 monitors the actual output current of the instrument: When the out-
put current is higher than the upper limit Ilim set by pin 9, the instrument
outputs the current at the value of Ilim.
5.13 Restored to Factory Setting (System Reset)
This menu item is used to restore some parameter settings to factory setting
values.
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Press the Up/Down key or turn the knob to select the System Reset and
press [Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
• No: Default value, indicates the instrument cancels this menu setting.
• Yes: Indicates the instrument restores the factory default settings.
4. After the parameter settings are complete, press [Enter].
The parameters affected by System Reset and the parameter values after
reset are shown in the following table.
Table 5–3 Initial value of the parameter
Category
Parameter Initial Value
Main
interface
Voltage setting: Vset One percent of the rated
voltage of the
instrument
Current setting: Iset One percent of the rated
current of the instrument
Upper limit of voltage: Vlim Upper limit value: One
percent of the rated volt-
age of the instrument
Upper limit of current: Ilim One percent of the rated
current of the instrument