Technical Specification
Parameter IT6010D-80-300
Working Temperature
0~50℃
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
30KG
Note: 1. Models without emergency stop module (i.e. AC contactor not included), other AC in-
put voltage ranges are required for customization. Models without emergency stop module and
assembled to the cabinet, with AC input voltage in the range of 198~264V, need to be custom-
ized while derating by 50%. Models with emergency stop module (including AC contactor) only
support 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.1.3 IT6015D-80-450
Parameter IT6015D-80-450
Rated value
Output Voltage
0~80V
( 0 ℃-50 ℃) Output Current
0~450A
Output Power
0~15kW
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.001V
Current 0.01A
Power 0.001kW
Read Back Resolution
Voltage
0.001V
Current 0.01A
Power 0.001kW
Setup Accuracy Voltage
≤0.02% +0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Read Back Accuracy Voltage
≤0.02% +0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Ripple Voltage ≤120mVpp(MAX:≤200mVpp)
Copyright © Itech Electronic Co., Ltd.
130