EasyManuals Logo
Home>ITech>Power Supply>IT6000D Series

ITech IT6000D Series User Manual

ITech IT6000D Series
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
Technical Specification
Remote Sense Compensa-
tion Voltage
≤8V
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1500V
Working Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
Note:
1. Models without emergency stop module (i.e. AC contactor not included), other AC input volt-
age ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.5 1500V
6.1.5.1 IT6018D-1500-40
Parameter IT6018D-1500-40
Rated value
Output Voltage
01500V
( 0 -50 ) Output Current
040A
Output Power
018kW
Line Regulation Voltage
≤0.01%FS
±(of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.1V
Current 0.001A
Power 0.001kW
Copyright © Itech Electronic Co., Ltd.
151

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6000D Series and is the answer not in the manual?

ITech IT6000D Series Specifications

General IconGeneral
BrandITech
ModelIT6000D Series
CategoryPower Supply
LanguageEnglish

Related product manuals