Technical Specification
Remote Sense Compensa-
tion Voltage
≤8V
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70℃
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1500V
Working Temperature
0~50℃
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
Note:
1. Models without emergency stop module (i.e. AC contactor not included), other AC input volt-
age ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.5 1500V
6.1.5.1 IT6018D-1500-40
Parameter IT6018D-1500-40
Rated value
Output Voltage
0~1500V
( 0 ℃-50 ℃) Output Current
0~40A
Output Power
0~18kW
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%FS
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.1V
Current 0.001A
Power 0.001kW
Copyright © Itech Electronic Co., Ltd.
151