Technical Specification
Parameter IT6018D-500-120
Note:
1. Models without emergency stop module (i.e. AC contactor not included), other AC input volt-
age ranges are required for customization. Models without emergency stop module and as-
sembled to the cabinet, with AC input voltage in the range of 198~264V, need to be customized
while derating by 50%. Models with emergency stop module (including AC contactor) only sup-
port 380VAC±10% for standard AC input voltage, 480VAC±10% voltage is required for
customization.
6.1.4 800V
6.1.4.1 IT6006D-800-25
Parameter IT6006D-800-25
Rated value ( 0 ℃-50 ℃)
Output Voltage
0~800V
Output Current
0~25A
Output Power
0~6kW
Line Regulation Voltage
≤0.01%FS
±(%of Output+Offset)
Current ≤0.05%FS
Load Regulation Voltage
≤0.02%S
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Read Back Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Setup Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Read Back Accuracy Voltage
≤0.02% + 0.02%FS
( within 12 months, 25℃
±5℃)
Current ≤0.1% + 0.1%FS
±(%of Output+Offset)
Power ≤0.5% + 0.5%FS
Ripple Voltage ≤800mVpp(MAX:≤1.2Vpp)
Copyright © Itech Electronic Co., Ltd.