Output Commands
Copyright© Itech Electronic Co., Ltd. 31
Unit
A mA
*RST Value
MAX
Example
CURR 3A, CURR 30mA, CURR MAX, CURR MIN
Query syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Arguments
[MIN|MAX]
Example
CURR?, CURR? MAX, CURR?MIN
Returns
<NR2>
[SOURce:]CURRent[:LEVel]:UP[:IMMediate][:AMPLitud
e]
This command is used to increase a current step for current channel.
Command syntax
[SOURce:]CURRent[:LEVel]:UP[:IMMediate][:AMPLitude]
Arguments
None
Related Command
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
[SOURce:]CURRent[:LEVel]:DOWN[:IMMediate][:AMPL
itude]
This command is used to decrease a current step for current channel.
Command syntax
[SOURce:]CURRent[:LEVel]:DOWN[:IMMediate][:AMPLitude]
Arguments
None