Output Commands
Copyright© Itech Electronic Co., Ltd. 36
Example
VOLT:PROT? VOLT:PROT? MAX
Returns
<NR2>
[SOURce:]VOLTage:PROTection:TRIPed?
This command is used to query the OVP trigger status.
Command syntax
[SOURce:]VOLTage:PROTection:TRIPed?
Arguments
None
[SOURce:]VOLTage:PROTection:CLEar
This command is used to clear the protection status.
Command syntax
[SOURce:]VOLTage:PROTection:CLEar
Arguments
None
[SOURce:]VOLTage:LIMIT[:LEVel]
This command is used to set the upper limited voltage.
Command syntax
[SOURce:]VOLTage:LIMIT[:LEVel]
Arguments
num|Min|Max|def
Unit
kV|V|mV
Query syntax
[SOURce:]VOLTage:LIMIT[:LEVel]?