IEEE-488 Commands
Copyright© Itech Electronic Co., Ltd. 50
Command syntax
*TRG
Arguments
None
Related Command
TRIG
*SAV
This command can save the current setups of power supply to specified
memory. These setups contains current setups, voltage setups, max voltage
set and min voltage set
Command syntax
*SAV<NRf>
Arguments
1-27
Example
*SAV 3
Related Command
*RCL
*RCL
This command can recall the setups you saved before from the specified
memory.
Command syntax
*RCL<NRf>
Arguments
1-27
Example
*RCL 3
Related Command
*SAV
*TST?
This command is used to query the self-test by the instrument. 0 indicates that
self-test succeeds; other Arguments indicate self-test fails. In addition, in case
of failure, an error information will be generated to describe failure reason.