Output Commands
Copyright© Itech Electronic Co., Ltd. 35
Unit
None
*RST Value
OFF
Example
VOLT:PROT:STAT 1, VOLT:PROT:STAT ON
Query syntax
[SOURce:] VOLTage:PROTection:STATe?
Arguments
None
Example
VOLT:PROT:STAT?
Returns
<0|1>
[SOURce:]VOLTage:PROTection[:LEVel]
This command is used to set the protection voltage upper limit of the power
supply.
Command syntax
[SOURce:] VOLTage:PROTection[:LEVel] <NRf>
Arguments
MIN TO MAX|MIN|MAX
Unit
V | mV
*RST Value
MAX
Example
VOLT:PROT 30V VOLT:PROT MAX
Query syntax
[SOURce:] VOLTage:PROTection[:LEVel]?
Arguments
[MIN|MAX]