Function and Features
Copyright ©ITECH Electronic Co., Ltd. 13
current.Only when the actual current value is lower than the setting current value,can the
power supply works in CV mode.And the CV indicator lamp will be lit.
If the actual current value is limited by the setting current value or rated current,then
IT6512 will change to CC mode.And the CC indicator lamp will be lit.
3.7 Save operation
IT6512 can enable you to save some often used parameters in nonvolatile memory up to
100sets.So that you can recall the parameters quickly.The following ways can help you
achieve the save and recall operations:by pressing composite button +
(Save) button or through command *SAV,*RCL.Save operation should work in with
GROUP.Each GROUP can save 10sets,IT6512 includes 10 GROUP from 0-9.
Save parameters include setting voltage and setting current
Save method:
Using composite button + +number keys 1…9,and then pressing
button to save the preset value into specified memory region.
Using button +number keys 1-9,and then pressing button to recall the
saved parameters from specified memory region.
3.8 Trigger operation
Please select the trigger mode in the menu setup before you start a trigger operation.
Before you want to run a list sequence file,please provide a trigger signal by press
composited button + (trigger).During the list file running,the button
(trigger) will be alight.
3.9 Menu Operation
Press + (Menu) to enter the menu function.View the meun in VFD,and use
right and left direction key or knob to scroll through the complete menu list as following.If
press button,you could get the selected menu function.Press back to the
previous menu selection page.
Menu of IT6512 and IT6513
SYSTEM
Initialize
Rst(Def)
Restore to factory defaults
Remain last shutdown parameters
Bus
Memory MEMORY
Work with recall button to recall 100sets saved
parameters